Product Information

Overview

An accurate and fast system for positioning electrodes at standard locations

Developed by Soterix Medical Research, the EASYstrap™ can be used to position Soterix Medical EASYpads at standard tDCS/tACS/tRNS locations, maximizing reproducibility and subject comfort. The custom head-gear with engraved land-mark finder and ruler makes the EASYstrap the simplest system to use for 1x1. Simply identify the standard tDCS/tES electrode locations, snap in the EASYpads, and secure the EASYstrap to the subjects head with a single safety buckle click. Additional EASYstrap benefits include:

  • Robust fixed position, even under moderate subject motion
  • Access to EASYpads access during stimulation, for electrode monitoring and re-wetting during prolonged application
  • Precise reproduction of electrode positioning for clinical studies

EASYstraps are engineered in three adults sizes (S, M, L) and three pediatric sizes (pS, pM, pL). Select from two connectors: velcro for convenient and secure connection or SAFETY BUCKLE for a snap-connection with extra robustness.

What's included

1 EASYstrap

Tech Specs

EASYstrap for Unilateral Motor

Model: EASYstrap M1-SO (adult: S, M, L; pediatric: pS, pM, pL)
Electrodes:5×7cm or 5×5cm EASYpads
Current: 1-2 mA Duration: 10-40 minutes

  • Excitability changes induced in the human motor cortex by weak transcranial direct current stimulation. Nitsche MA, Paulus W.
  • Transcranial direct current stimulation (tDCS) and robotic practice in chronic stroke: the dimension of timing. Giacobbe V1, Krebs HI, Volpe BT, Pascual-Leone A, Rykman A, Zeiarati G, Fregni F, Dipietro L, Thickbroom GW, Edwards DJ.
  • Migraine prophylaxis by anodal transcranial direct current stimulation, a randomized, placebo-controlled trial. Auvichayapat P1, Janyacharoen T, Rotenberg A, Tiamkao S, Krisanaprakornkit T, Sinawat S, Punjaruk W, Thinkhamrop B, Auvichayapat N.

EASYstrap for Bilateral Motor

Model: EASYstrap C3-C4 (adult: S, M, L; pediatric: pS, pM, pL)
Electrodes:5×7cm or 5×5cm EASYpads
Current: 1-2 mA Duration: 10-40 minutes

  • A Comparison between Uni- and Bilateral tDCS Effects on Functional Connectivity of the Human Motor Cortex. Sehm B, Kipping J, Schäfer A, Villringer A, Ragert P.
  • Dual-tDCS Enhances Online Motor Skill Learning and Long-Term Retention in Chronic Stroke Patients. Lefebvre S, Laloux P, Peeters A, Desfontaines P, Jamart J, Vandermeeren Y.
  • Bilateral transcranial direct current stimulation modulates activation-induced regional blood flow changes during voluntary movement. Paquette C, Sidel M, Radinska BA, Soucy JP, Thiel A.

EASYstrap for Symmetric lateralized DLPFC-1

Model: EASYstrap Dlpfc-1 (adult: S, M, L; pediatric: pS, pM, pL)
Electrodes: 5x5cm or 5x7cm EASYpads
Current: 2 mA Duration: 10-40 minutes

  • The sertraline versus electrical current therapy for treating depression clinical study (select-TDCS): results of the crossover and follow-up phases. Valiengo L, Benseñor IM, Goulart AC, de Oliveira JF, Zanao TA, Boggio PS, Lotufo PA, Fregni F, Brunoni AR.
  • Acute working memory improvement after tDCS in antidepressant-free patients with major depressive disorder. Oliveira JF, Zanão TA, Valiengo L, Lotufo PA, Benseñor IM, Fregni F, Brunoni AR.

EASYstrap for Asymmetric, left targeted DLPFC-2

Model: EASYstrap Dlpfc-2 (adult: S, M, L; pediatric: pS, pM, pL)
Electrodes: 5x5 cm or 5x7cm EASYpads
Current: 1-2 mA Duration: 10-40 minutes

  • Transcranial direct current stimulation for depression: 3-week, randomized, sham-controlled trial. Loo CK, Alonzo A, Martin D, Mitchell PB, Galvez V, Sachdev P.
  • The preoperative anesthesia evaluation. Schmiesing CA, Brodsky JB.